Addressable Fire Alarm System

   The POLON 4100 control panel is recommended for protection of various types of buildings, especially small size premises such as hotels, office buildings, banks, warehouses, historical buildings, „intelligent” buildings, etc. The possibility of addressing linear elements allows the identification of the place of fire with an accuracy of a single detector. The control panel allows also control and monitor of external security devices such as gates fire, smoke vents, etc. and to provide information about the fire to the monitoring station in both digital and analog version. After receiving the alarm signal, depending on the programmed alarm variant, the POLON 4100 control panel activates signalling devices and output relays inside the control panel as well as control lines in the form of linear control units.

The POLON 4200 fire alarm control panel is designed to integrate all elements of the addressable POLON 4000 fire alarm system

The control panel coordinates the operation of all system units and decides on the activation of the fire alarm, the control of mutual signaling and fire protection equipment, as well as the transmission of information to the monitoring center

    POLON 4500 fire extinguishing system control panel is designed to detect and activate fire alarm and monitor the performance of automatic fire extinguishing systems The POLON 4500 control unit is a multi-processor unit that has two (extra) processor circuits

     In case of damage to the main processor of the control unit, without any interruption in the operation of the system, its operation is carried out by the latter

     The 4900 Polon Alpha control panel is suitable for integration with other systems within the framework of so-called “smart” buildings The ability to address linear elements allows the location of a fire to be identified with the accuracy of a detector

      Monitor external security devices such as fire gates, smoke vents, etc. and provide fire information to the monitoring station in both digital and analog versions after receiving the alarm signal depending on the type of programmed alarm

 POLON 6000 Fire Alarm Control Panel 

     The control panel coordinates the operation of all the devices in the system and decides on fire alarm, fire alarm and fire protection devices, and the transmission of fire information to the monitoring center or monitoring system. The POLON 6000 is recommended for fire protection in medium, large and very large buildings, especially those with complex structures. Includes a variety of features such as CPU Redundancy to replace the processor in case of special problems or modularity and user-friendly configuration and 10-inch color touch display and the ability to upgrade and install up to 99 controllers on a Polon 6000 panel for massive and ultra-wide projects 

The TSR-4000 addressable repeater center is a microprocessor-based unit designed to work with POLON 4000 system fire alarm control panels. It functions as a signaling and remote operation unit. It is even possible to connect 16 TSR-4000 terminals to one control panel. The TSR-4000 terminal provides the possibility of repeating the information sent by the fire alarm control panels of the POLON 4000 system

Addressable Multimode Optical Smoke Detector
The DOR-4046 detector is designed for detecting visible smoke at the start of the flame-free stage,

 At the moment of fire danger, the detector sends an alert signal to the fire alarm control panel.

Addressable multimode optical smoke detector.

     The DUR-4046 detector is designed to detect visible smoke at the start of the stage without flame, at the moment of fire danger, the detector sends an alarm signal to the fire alarm control panel.

The DUO-6046 analogue heat, smoke and carbon monoxide detector is designed to detect a combination of visible smoke, temperature rise and the presence of carbon monoxide in the early stages of a fire The detector is resistant to air movement and air pressure changes The use of a double smoke sensor (IR and UV range) and doubled thermal sensors ensure a high resistance to false alarms caused by water vapor or dust

The DUO-6046AD is an analog detector with self-regulation feature that ensures a constant sensitivity level over the detector’s working time, even if any dirt appears inside the measuring chamber. When it exceeds a certain dirt level, the detector sends information about the maintenance requirement to the control panel. Any errors, technical alarms and activation of the internal short circuit insulation are indicated by flashing yellow of LED indicators.

Addressable multi-mode global temperature detector

The detector TUN-4046 is designed to detect the increase in heat that may occur in the initial stage of a fire. At the moment of fire danger, the detector sends an alarm signal to the fire alarm control panel. It is also possible to program the thermal class of the detector

     Universal heat (temperature) detector TUN-6046 is designed to detect fire hazard in indoor places where in the initial stage of fire there may be a rapid rise in temperature or the temperature may exceed the predetermined danger level

     The detector can be programmed from the control panel Depending on the temperature type selected, the class detector can operate as a constant temperature, rate of rise and constant/rate of rise detector

Addressable multi-mode multi-sensor detector
      The DOT-4046 processor-based dual-sensor detector is designed to detect smoke and temperature rise at the same time as a fire in the early stages of development.
 This detector has the ability to program different modes of operation, which allows interaction or independent operation of the smoke and temperature detector
 

     The DUT-6046 multi-sensor smoke and heat detector is designed to detect visible smoke and rising heat, which indicates the initial stage of open fire ignition This detector is characterized by significant resistance to air velocity and air pressure changes The use of double smoke detection systems (IR and UV) as well as double heat detection systems ensures increased resistance to false alarms DUT-6046 detectors can operate on POLON 4000/POLON 6000 addressable fire alarm panel lines/loops

     The working principle of smoke detection is based on the Tyndall effect. The light is reflected from the smoke particles that enter the measuring chamber The light emitted from the light-emitting diode, after reflecting the smoke particles, is received by the photo-receiving element and changes the light flow An increase in temperature in the vicinity of the detector changes the resistance of one or two thermistors 

     The DUT-6046AD multi-sensor smoke and heat detector is designed to detect visible smoke and temperature rise, which indicates the initial stage of open fire ignition :This detector is characterized by significant resistance to air velocity and air pressure changes

   The use of double smoke detection systems (IR and UV) as well as double heat detection systems ensures increased resistance to false alarms

Addressable multi-mode smoke and flame detector
The DPR-4046 detector is designed to detect visible smoke and flame simultaneously with the initial stage of open fire ignition The interaction of the smoke and flame sensor allows for faster fire detection, which is accompanied by a visible flame from the beginning

DOP-6001 addressable beam smoke detector (beam detector) is designed to detect smoke at the start of a fire in places where point detectors are not used (for example, in large industrial sheds)

It is especially suitable for the protection of interior spaces, where there is a possibility of smoke appearing during a fire and because of the large space, it is necessary to install more point smoke detectorsThese detectors can work exclusively in the detection lines of the POLON-ALFA production fire alarm system:

This type of DOP-6001R detector can be used directly in the addressable loop lines of the 6000, POLON 4000 system and in the conventional lines of the IGNIS 1000/2000 system

The DUO-6046K smoke detector is designed to detect visible smoke along with most fires, monitor air in ventilation ducts, and other channels. Due to the cross-sectional area of the duct, rapid air movement, and other factors, direct installation of the detector in the duct is not possible.
The DUO-6046K detector can detect all regular test fires of optical smoke detectors. “It is very sensitive to both visible and invisible smoke.”
This is an addressable detector equipped with an internal short-circuit isolator, designed to work on addressable control panels of POLON 4000 and POLON 6000 for detection lines.

Addressable (MCP) Manual Call Points ROP-4001M and ROP-4001MH are designed to send fire related information to the fire alarm control panel by the person who notices the fire and manually activates the MCP The Manual Call Point (MCP) can only be connected to the detection lines/loops of the POLON 4000 fire alarm system

The Manual Call Points are designed for wall-mounted installation (Facade installation requires the use of a special cover frame that can be ordered separately)

     SAL-4001 addressable acoustic sirens are designed for acoustic fire alarm signaling They are intended only for operation on addressable detection lines of POLON 6000, 3000 and POLON 4000 systems

       When all the parameters programmed by the panel are analyzed, the alarms are activated by the control panel

     The SAW-600X addressable acoustic sounds are designed for acoustic fire signaling with audio messages This equipment is only intended for operation in POLON 6000 and POLON 4000 addressable detection lines

     When all scheduled metrics are analyzed, they are activated by the control panel 

     Sounder Beacon SAB-600X addressable flasher siren is designed for audio and optical fire signaling They can only work on POLON 6000 and POLON 4000 fire alarm control panels’ addressable detection lines/loops

     For proper operation, the element needs two supply voltages:
– from the detection line (power loop)
– from an external power source (9V battery or secondary power supply)

The EKS-6040 interface is equipped with 4 low voltage inputs

Activation (using its relay contacts) of fire protection and fire alarm devices Monitoring the status of each device Low voltage (LV) inputs of the element allow you to connect independent, potential-free contacts that are normally closed or normally open

The high voltage (HV) component of the input allows you to connect independent contacts at voltages up to 230 VAC or 220 VDC

The EKS-6004 interface is equipped with 4 outputs

Activation (using its relay contacts) of fire protection devices and fire alarm panels Monitoring the status of each device Low voltage (LV) inputs of the element allow you to connect independent, potential-free contacts that are normally closed or normally open do

The high voltage (HV) component of the input allows you to connect independent contacts at voltages up to 230 VAC or 220 VDC

The EKS-6022 interface is equipped with 2 low voltage inputs and 2 outputs    

     Activation (using relay contacts) of fire extinguishing and fire alarm devices Monitoring the status of each device Low voltage (LV) inputs of the element allow you to connect independent, potential-free contacts that are normally closed or normally open

     The high voltage (HV) component of the input allows you to connect independent contacts at voltages up to 230 VAC or 220 VDC

The EKS-6044 element is equipped with 4 low voltage inputs and 4 outputs

Activation (using its relay contacts) of fire protection and fire alarm devices Monitoring the status of each device Low voltage (LV) inputs of the element allow you to connect independent, potential-free contacts that are normally closed or normally open

The high voltage (HV) component of the input allows you to connect independent contacts at voltages up to 230 VAC or 220 VDC

EKS-6202 element is equipped with 2 high voltage inputs and 2 outputs

Low voltage inputs (LV) element allow you to connect independent and unpotential contacts, which are usually closed or usually open. The input high voltage (HV) component allows you to connect independent contacts at voltages up to 230 VAC or 220 VDC. Suitable for indoor and outdoor facilities.

The EKS-6000 type elements can only work on addressable detection lines of POLON 6000 series panels.

EKS-6222 equipped with 2 high voltage inputs and 2 low voltage inputs and 2 outputs

EKS-6000 type addressable I/O elements are dedicated for:

  • Activation (with its relay contacts) of fire alarm and extinguishing systems
  • Monitoring the performance of controlled devices
  • Monitor the status of each device

The element’s low voltage (LV) inputs allow you to connect independent, potential-free contacts that are normally closed or normally open The high voltage (HV) component of the input allows you to connect independent contacts at voltages up to 230 VAC or 220 VDC

The WZ-31 alarm indicator is designed for repetitive optical signaling of the status of a detector or a set of detectors in fire alarm systems It can be connected to conventional or addressable detector lines of various brands

The WZ-31 optical alarm indicator signals the alarm status of one or at least one of the mutual detectors by a red LED diode

The G-40 base is designed to install model 40, 4043 and 4046 detectors (such as DOR-40, DUR-4043) on the ceiling and to connect detection lines to them. There is installed. The base is equipped with a special ring for more beauty and this allows it to become a beautiful and sealed place for side connections