+982188530034-7

+982188530039

info@asec-int.com

Industrial Fire Alarm Equipment

      Optical Smoke Detector EX Series (intrinsically safe non-sparking for high-risk flammable or explosive environments) The DUR 40Ex optical smoke detector is designed to detect visible smoke in the early stages of a fire 

     The detector is installed in the suitable anti-spark separator in areas with explosion risk. At the moment of fire danger, the detector sends an alarm signal to the fire alarm control panel

An EX (intrinsically safe) series heat detector, the TUN-38EX was designed to detect rapid heat increases during fires in the early stages of its development. The detector is installed behind a suitable anti-spark separator in areas with a risk of explosion

At the moment of fire danger, the detector sends an alarm signal to the fire alarm control panel

     PUO-35 (UV FLAME Detector) It is a flame detector with UV waves and is designed to detect the flame at the same time as the fire in the early stages of its development. At the moment of fire danger, the detector sends an alarm signal to the fire alarm control panel.

     In addition, PUO-35EX, which is black in color, is an intrinsically safe UV flame detector from the EX series for explosive environments 

The PPW-40REx detector provides high flame detection efficiency of hydrocarbon-containing fuels in explosive risk environments, with high safety against false alarms due to a set of three infrared sensors that work in different bands.

This detector is intended for areas with high explosion risk, it is designed for various indoor and outdoor applications

     DOP-6001 is designed to detect smoke at the start of a fire. It is especially suitable for protecting indoor spaces where smoke is likely to emerge during a fire and due to large spaces, it is not possible to install a large number of spot smoke detectors.

     Conventional DOP-6001R beam smoke detectors are equipped with fire alarm outputs and fault relays, enabling them to work in detection lines of all fire alarm system control panels as well as in burglary alarm systems.

DUR-40K smoke detector duct, which has a maximum current consumption of 60 microamps in standby mode and 20 milliamps in fire mode, and is capable of detecting TF2D, TF4D, and TF8D fires

The air speed in the channel can be in the range of 1 m/s to 20 m/s The length of the air sampling tube can be one of the selected items of 240, 600, 900 or 1200 mm The detector has an IP65 detector protection degree

In addition, the ability to announce the accumulation of pollution (dust) on the surface of the detector and reflector is one of the unique capabilities of this detector

 

     The G-33 base is designed to connect fire detectors to fire detection and alarm systems It is suitable for use with PUO-35Ex intrinsically safe detectors The G-33 base is equipped with four terminals and has two cables for input and output

     The wire for mounting the base ceiling has a ring that is closed with three screws to prevent removal of the detector without tools

The G-40 base is designed to install model 40, 4043 and 4046 detectors (such as DOR-40, DUR-4043) on the ceiling and to connect detection lines to them. There is installed. The base is equipped with a special ring for more beauty and this allows it to become a beautiful and sealed place for side connections

Conventional flame detector PPW-40Rex

Hold on the product for more information

Explosion proof IR3 flame detector

High safety against false alarms due to a set of three infrared sensors working in different bands
Catalog Download