Conventional Fire Alarm System

    The IGNIS 2040 microprocessor based fire detection and alarm control panel is designed for fire detection and fire danger signalling after receipt of a fire signal from interoperating fire detectors and manual call points.
    It enables actuation of additional signalling devices and signal transmission to a fire monitoring system. Executed in the Surface Mount Technology, the panel is equipped with expanded diagnostics and self-monitoring circuits that guarantee long-term and unfailing early fire warning system operation.
     The control panel is dedicated for fire protection of small premises: warehouses, stores, small offices, remote telecommunication objects (containers), etc.

     The IGNIS 1080 fire alarm panel is designed to detect and signal fire after receiving a fire alarm from detectors or manual call points
Fire alarm panel It can control the signaling devices (acoustic, optical-acoustic) and send the alarm status to the monitoring station. Using internal relays, the panel can activate the fire protection devices and monitor its status. Fire alarm panel It is designed for installation in small places such as warehouses, shops, small companies, hotels, etc    

It is currently out of production

     The IGNIS 1240 fire control panel is designed to detect and signal fire after receiving a fire alarm from detectors or manual call points

    The control panel can control the signaling devices (acoustic, optical-acoustic) and send the alarm status to the monitoring station. Using internal relays, the control panel can activate the fire protection devices and monitor its status. The control panel is designed for installation in medium-sized objects such as warehouses, shops, companies, hotels, etc. It is designed and manufactured according to the PN-EN 54-2 standard

It is currently out of production

Conventional optical smoke detector  
   The DOR-40 detector is designed to detect a visible smoke at a start of a fire’s flameless stage, In the moment of fire hazard the detector transmits an alarm signal to the fire alarm control panel.

   The DOR-40 detectors can operate in  lines/loops of the IGNIS 1000 or on the side line of ADC-4001M adapter in POLON 4000 fire alarm control panels.

Conventional optical smoke detector

    The DOR-40 detector is designed to detect a visible smoke at a start of a fire’s flameless stage, In the moment of fire hazard the detector transmits an alarm signal to the fire alarm control panel.

    The DOR-40 detectors can operate in  lines/loops of the IGNIS 1000 or on the side line of ADC-4001M adapter in POLON 4000 fire alarm control panels.

Conventional, fixed temperature rate-of-rase heat detector

    The TUP-40 fixed temperature/rate-of-rise heat detector reacts to a rise in temperature occurring during a fire. The detector works as a fixed temperature detector when temperature excesses the threshold pursuant to a given class, and as a rate-of-rise detector during a sudden rise in temperature. In the moment of fire hazard the detector transmits an alarm signal to the fire alarm control panel.

    The TUP-40 detectors can operate in  lines/loops of the IGNIS 1000/2000 or on the side line of ADC-4001M adapter in POLON 4000 fire alarm control panels.

Conventional, heat and smoke detector.

    The DOT-40 multi -sensor (optical smoke and heat) detector is designed for detection of a smoke and a rise in temperature concurrent with a fire at its early development stage. At the time of the simultaneous detection of both the increase in temperature and smoke detector transmits an alarm signal to the fire alarm control panel. The use of two sensors eliminates the possibility of false alarms and allows the use of detectors in areas where due to the amount of dust or dirt that was not previously possible.

    The DOT-40 detectors can operate in  lines/loops of the IGNIS 1000 or on the side line of ADC-4001M adapter in POLON 4000 fire alarm control panels.

nd smoke

Conventional, heat and flame detector

   The heat sensor is a thermistor, which reacts to the rise of temperature occurring during the first stage of a fire. At the time of the simultaneous detection of both the increase in temperature and flame detector transmits an alarm signal to the fire alarm control panel. The use of two sensors eliminates the possibility of false alarms and allows the use of detectors in areas where due to the amount of dust or dirt that was not previously possible.

    The TOP-40 detectors can operate in  lines/loops of the IGNIS 1000 or on the side line of ADC-4001M adapter in POLON 4000 fire alarm control panels.

     Outdoor Conventional Fire Alarm Manual Call Point – HermeticROP-63H is designed to send fire information to the mutual fire alarm control panel by the person noticing the fire, who, according to safety principles, presses the trigger with two fingers to open it and then presses the black button     

SAW-6102 model audio sirens are designed for audio fire alarm signaling It is possible to synchronize the sound of several voices working in the same acoustic area They are dedicated to work with a variety of control panels with suitable power supply output Electronic circuits with a piezoelectric sounder are installed in a red housing made of flame-resistant materials

SAW-610X series audio sirens are designed for audio signaling of fire alarm with audio messages It is possible to synchronize the sound of several voices working in the same acoustic area Electronic circuits with a piezoelectric sounder are installed in a red housing made of flame-resistant materials

Sounder Beacon SAB-610X series is designed for audio and visual fire signaling in one audio tone They are designed to work with all fire alarm control panels that provide the appropriate supply voltage at their outputs This siren has a direct 12-24 volt power supply and produces a sound intensity of 114 dbA, which is suitable for industrial areas with high ambient noise

The WZ-31 alarm indicator is designed for repetitive optical signaling of the status of a detector or a set of detectors in fire alarm systems It can be connected to conventional or addressable detector lines of various brands

The WZ-31 optical alarm indicator signals the alarm status of one or at least one of the mutual detectors by a red LED diode

The G-40 base is designed to install model 40, 4043 and 4046 detectors (such as DOR-40, DUR-4043) on the ceiling and to connect detection lines to them. There is installed. The base is equipped with a special ring for more beauty and this allows it to become a beautiful and sealed place for side connections

Conventional control center IGNIS 1240

Hold on the product for more information
This control center includes 16 conventional zones with the ability to support 32 conventional equipments on each zone along with 2 conventional alarm lines