Addressable Gas Detection Control Panel for up to 99 Sensors - CDG 6000 99
The CDG 6000 Addressable Gas Detection Panel is designed to detect and signal combustible gas leaks and hazardous concentrations of carbon monoxide after receiving information from gas detectors with which they collaborate. The control panel can work with up to 99 addressable gas detectors of type PSG-6000. The control panel has relay outputs for external device control, special gas cutoff valve control outlet and control inputs.
Addressable Gas Detection Control Panel for up to 16 Sensors - CDG 6000 16
The CDG 6000 Addressable Gas Detection Panel is designed to detect and signal combustible gas leaks and hazardous concentrations of carbon monoxide after receiving information from gas detectors with which they collaborate. The control panel can work with up to 16 addressable gas detectors of type PSG-6000. The control panel has relay outputs for external device control, special gas cutoff valve control outlet and control inputs.
Addressable Gas Detection Control Panel for 2, 4 or 8 Sensors - mCDG 6000
The CDG 6000 Addressable Gas Detection Panel is designed to detect and signal combustible gas leaks and hazardous concentrations of carbon monoxide after receiving information from gas detectors that cooperate with it. The control panel can work with up to 16 addressable gas detectors of type PSG-6000. The control panel has relay outputs for external device control, special gas cutoff valve control outlet and control inputs.
Addressable Loop Powered CO2 Gas Sensor - PSG 6103
PSG-6103 addressable gas detectors are designed to detect and monitor the presence of flammable and toxic gases in potentially hazardous areas, particularly in garages and boiler rooms. When it goes beyond them, the detectors send data to CDG 6000. The control panel initiates the ventilation to remove excess harmful gases from the room and may also send a control signal to the valve. PSG-6103 detectors operate only on the monitoring lines of the addressable CDG 6000 gas detection panels. They don’t need an extra external power supply. They are fed from the detection line.
Addressable CO2 Gas Sensor with External Power - PSG 6003
PSG-6003 addressable gas detectors are designed to detect and monitor the presence of flammable and toxic gases in potentially hazardous areas, particularly in garages and boiler rooms. When it goes beyond them, the detectors send data to CDG 6000. PSG-6003 detectors operate only on the monitoring lines of addressable CDG 6000 gas detection panels. They require an external power supply of 9-30 volts of additional DC.
Addressable LPG Gas Sensor with External Power - PSG 6002
PSG-6002 addressable gas detectors are designed to detect and monitor the presence of flammable and toxic gases in potentially hazardous areas, especially in garages and boiler rooms. When it goes beyond them, the detectors send data to the CDG 6000. The control panel initiates the ventilation to remove excess harmful gases from the room and may also provide a control signal to the gas-cut valve. PSG-6002 detectors operate only on the monitoring lines of the addressable CDG 6000 gas detection panels. They require an external power supply of 9-30 volts of additional DC.
Addressable CNG Gas Sensor with External Power - PSG 6001
PSG-6001 addressable gas detectors are designed to detect and continuously monitor the presence of flammable and toxic gases in potentially hazardous areas, especially in boiler rooms and garages. When it goes beyond them, the detectors send data to the CDG 6000. The control panel initiates the ventilation to remove excess harmful gases from the room and may also provide a control signal to the gas-cut valve. PSG-6001 detectors work only on the monitoring lines of addressable CDG 6000 gas detection panels. They require an external power supply of 9-30 volts of additional DC.
Conventional CO2 Gas Sensor with 24 VDC Power - ASG 2003
The detector continuously analyzes the concentration of gas in the room and compares it with the values of the respective alarm thresholds. Each detector has three alarm thresholds that correspond to precisely the concentration of the given gas in the air. When it exceeds the specific threshold, the detector’s optical indicator is activated and outputs suitable for controlling the external audio light are activated. Failure modes (decoder failure, power failure, absence of sensor module) are signaled by a separate LED and to a programmable relay output.
Conventional CO2 Gas Sensor with 220 VAC Power - ASG 2003HV
The detector continuously analyzes the concentration of gas in the room and compares it with the values of the respective alarm thresholds. Each detector has three alarm thresholds that correspond to precisely the concentration of the given gas in the air. When it exceeds the specific threshold, the detector’s optical indicator is activated and outputs suitable for external audio light control are activated. Failure modes (detector failure, sensor failure, power failure, absence of sensor module) are signaled by a separate LED and a programmable relay output.
Conventional LPG Gas Sensor with 24 VDC Power - ASG 2002
ASG-2002 independent gas detectors are designed to detect flammable and toxic gases in hazardous areas such as garage, car parking and boiler room etc. When it exceeds the specific threshold, the detector’s optical indicator is activated and has appropriate outputs for control. The external sound light is activated. It is also possible to start ventilating to ventilate and remove harmful gases from the room.
Conventional LPG Gas Sensor with 220 VAC Power - ASG 2002HV
ASG-2002HV stand-alone gas detectors are designed to detect flammable and toxic gases in hazardous areas such as garages, car parks and boiler rooms, etc When a certain threshold is exceeded, the optical indicator of the detector is activated and the appropriate outputs are controlled The external audio light is activated It is also possible to start to ventilate and remove harmful gases from the room
Conventional CNG Gas Sensor with 24 VDC Power - ASG 2001
Gas detectors ASG-2001 ASG-2000 is designed to detect flammable and toxic gases in dangerous areas such as garage, car parking and boiler room etc When a certain threshold is exceeded, the detector’s light indicator is activated and the appropriate outputs are controlled The external audio light is activated It is also possible to start to ventilate and remove harmful gases from the room
Conventional CNG Gas Sensor with 220 VAC Power - ASG 2001HV
ASG-2001HV self-propelled gas detectors of the ASG-2000 range are designed to detect flammable and toxic gases in dangerous areas such as garages, car parks and boiler rooms, etc. When a certain threshold is exceeded, the detectors light indicator is activated and The appropriate outputs are controlled. The external sound light is activated. It is also possible to start ventilation and remove harmful gases from the room