Fire Alarm and Extinguishing Control System

The IGNIS 1520M automatic fire extinguishing controller is designed for fire detection and control of conventional fire extinguishing equipment containing gas, liquid or aerosol, as well as monitoring the self-active extinguishing process

The controller works with standard 40 model range fire detectors and specialized PU-61 and PW-61 push buttons that allow manual activation and deactivation of the fire extinguishing process

The IGNIS 2500A automatic fire extinguisher control panel is designed for fire detection and control of fixed fire extinguishers containing gas, liquid or aerosol and monitoring the automatic extinguishing process

This is an addressable version of the IGNIS 2500 control panel, designed to work on addressable detection loops of the POLON 6000 system
This solution provides unique opportunities for the full cooperation of the POLON 6000 system and the IGNIS 2500 control panels, which then form an extinguishing subsystem

    POLON 4500 fire extinguishing system control panel is designed to detect and activate fire alarm and monitor the performance of automatic fire extinguishing systems The POLON 4500 control unit is a multi-processor unit that has two (extra) processor circuits

     In case of damage to the main processor of the control unit, without any interruption in the operation of the system, its operation is carried out by the latter

Conventional optical smoke detector  
   The DOR-40 detector is designed to detect a visible smoke at a start of a fire’s flameless stage, In the moment of fire hazard the detector transmits an alarm signal to the fire alarm control panel.

   The DOR-40 detectors can operate in  lines/loops of the IGNIS 1000 or on the side line of ADC-4001M adapter in POLON 4000 fire alarm control panels.

Conventional optical smoke detector

    The DOR-40 detector is designed to detect a visible smoke at a start of a fire’s flameless stage, In the moment of fire hazard the detector transmits an alarm signal to the fire alarm control panel.

    The DOR-40 detectors can operate in  lines/loops of the IGNIS 1000 or on the side line of ADC-4001M adapter in POLON 4000 fire alarm control panels.

Conventional, fixed temperature rate-of-rase heat detector

    The TUP-40 fixed temperature/rate-of-rise heat detector reacts to a rise in temperature occurring during a fire. The detector works as a fixed temperature detector when temperature excesses the threshold pursuant to a given class, and as a rate-of-rise detector during a sudden rise in temperature. In the moment of fire hazard the detector transmits an alarm signal to the fire alarm control panel.

    The TUP-40 detectors can operate in  lines/loops of the IGNIS 1000/2000 or on the side line of ADC-4001M adapter in POLON 4000 fire alarm control panels.

Conventional, heat and smoke detector.

    The DOT-40 multi -sensor (optical smoke and heat) detector is designed for detection of a smoke and a rise in temperature concurrent with a fire at its early development stage. At the time of the simultaneous detection of both the increase in temperature and smoke detector transmits an alarm signal to the fire alarm control panel. The use of two sensors eliminates the possibility of false alarms and allows the use of detectors in areas where due to the amount of dust or dirt that was not previously possible.

    The DOT-40 detectors can operate in  lines/loops of the IGNIS 1000 or on the side line of ADC-4001M adapter in POLON 4000 fire alarm control panels.

nd smoke

ROP-63(H) Red Manual Call point is of type B and has a unique cover

The degree of protection is designed and manufactured in two options IP30 and IP55 for indoor and outdoor applications

Manual Call point has European Union approval based on the EN54-11 standard

PU-61 Orange Manual Call point is type B and has a unique cover This Manual Call Point is approved by the European Union based on the EN12094-3 standard and is used for manual start of automatic fire extinguishing

PU 61 Blue Manual Call Point is type B and has a unique cover This Manual Call point is approved by the European Union based on the EN12094-3 standard and is used to manually stop automatic fire extinguishing when the process starts

     SE-1 discharge warning elements due to automatic shutdown; EVACUATE THE ROOM  which is written on the board SE-1 warning devices are designed as an evacuation warning for personnel present near the extinguished area, when the extinguishing process has started and an extinguishing agent is discharged

     SW-1 warning devices are designed as an evacuation warning for personnel present near the extinguished area, when the extinguishing process has begun and an extinguishing agent is discharged.
Alarm devices can work with the controller of the automatic fire extinguishing system IGNIS 1520M manufactured by POLON-ALFA

Unrivaled POLON 6000 panel

Hold on the product for more information.
This center is modular and has the ability to be configured flexibly. The center has a unique 10' color touch screen and supports CPU Redundancy, which ...
Download Catalog
POLON 6000 Fire Alarm